0.5T 1T 2T 5T 10T 15T 20T 30T 50T 60T 80T 100T Pancake load cell compress force sensor transducer
Model: YGX-DL103S1
Features & Applications:
Stainless steel construction
Max. capacity from 0.5t to 100t
Complies with OIML R60 regulations up to 3000d divisions
Hermetically sealed (IP68; IP69K)
Low profile and small deflection
Applications: Container and tank weighing; and Industrial batching control system
Option
Various cable lengths
Explosion-proof versions
Capacity: 0.5T~100T
Dimensions(mm):

Specification:
|
Rated capacity (Emax)
|
0.5 / 1 / 2.5 / 5 / 10 / 15 / 20 / 30 / 50 / 100 t
|
|
|
Accuracy class1)2)
|
0.03%
|
C3
|
|
|
Min. dead load
|
0
|
|
|
Rated output
|
2.0 ± 0.004 mV/V
|
|
|
Zero balance
|
±1% of Emax
|
|
|
Y-value
|
6000
|
10000
|
|
|
Repeatability error
|
< ± 0.015% of AL3)
|
< ± 0.010% of AL3)
|
|
|
Creep; 30 minute
|
< ± 0.030% of AL
|
< ± 0.017% of AL
|
|
|
Min. dead load output return (DR); 30 min
|
< ± 0.030% of AL
|
< ± 0.017% of AL
|
|
|
Temp. effect on
|
Min. dead load output
|
< ± 0.0023% of Emax/℃
|
< ± 0.0014% of Emax/℃
|
|
|
Rated output 2)
|
< ± 0.0020% of AL/℃
|
< ± 0.0012% of AL/℃
|
|
Temperature range
|
Compensated
|
-10 to + 40℃ [+ 14 to +104] (°F)
|
|
|
Operating
|
-40 to + 65℃ [- 40 to +149] (°F)
|
|
Safe storage
|
-40 to + 80℃ [- 40 to +176] (°F)
|
|
Excitation voltage
|
Recommended
|
5 ~ 15 V AC/DC
|
|
|
Maximum
|
15 V AC/DC
|
|
Terminal resistance
|
Excitation
|
766 ± 10Ω
|
|
|
Output
|
700 ± 3Ω
|
|
Insulation resistance @50VDC
|
> 5000 MΩ
|
|
|
Breakdown voltage
|
> 500 V AC
|
|
|
Seal type / IP rating
|
Hermetically welded / IP68 IP69k
|
|
|
Load limit
|
Safe
|
150% of Emax
|
|
|
Ultimate
|
300% of Emax
|
|
Material
|
Spring element
|
Stainless steel
|
|
|
Strain gauge
|
PEEK
|
|
Cable
|
Φ6.5; 4-wire; PVC
|
|
Cable length
|
0.5-10t
|
15-100t
|
|
|
6.0 m
|
12.0 m
|
|
Weight; approx
|
0.5-10t
|
15-30t
|
50t
|
100t
|
|
|
1.5 kg
|
2.0 kg
|
3.5 kg
|
7.0 kg
|
|
Fatigue life
|
> 1,000,000 cycles @Emax
|
|
|
Deflection at Emax; approx
|
< 0.5 mm
|
|
|
Barometric pressure effect on Zero Output
|
< 1.0 Vmin/kPa
|
|
Notes:
1) Error due to the combined effect of non-linearity and hysteresis
2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3) AL= Applied Load