Model: YGX-CL425D Analog sensor
Features & Applications:
This sensor can meet the range of 10 tons -100 tons of precision measurement.
Made of stainless steel, hermetically sealed, anti-oil, water, anti-corrosive gas and etc. media.
Column structure, anti-rotation, automatic reset.
Apply to electronic platform scales, vehicle inspection line, hopper scales and other electronic weighing devices.
Capacity: 10 T,20T, 30T, 40T, 50T
Dimensions(mm):

|
Size(mm)
Cap(t)
|
H1
|
H2
|
ØD1
|
ØD2
|
ØD3
|
| 10,15 |
130
|
80
|
44
|
50
|
80
|
| 20,30,40 |
150
|
80
|
44
|
50
|
80
|
| 50,60 |
210
|
120
|
44
|
50
|
80
|
4-core shielded cableØ6x12m
Wiring

Specification
| Precision |
C2 C3
|
|
Maximum number of verification
Intervals (n max)
|
2000 3000 |
|
Minimum load cell verification
intervals (v min)
|
Emax/5000 Emax10000 |
| Comprehensive error |
≤±0.030 F.S. ≤±0.020 F.S.
|
| Creep(30min) |
≤±0.023 F.S. ≤±0.016 F.S. |
| Temp. effect on output |
≤±0.017 % F.S. / 10ºC ≤±0.011 % F.S. / 10ºC
|
| Temp. effect on zero |
≤±0.023 % F.S. / 10ºC ≤±0.015 % F.S. / 10ºC
|
| Rated output |
2±0.002 mV / V
|
| Input impedance |
700±5Ω
|
| Output impedance |
700±5Ω
|
| Insulation |
≥5000MΩ/50VDC
|
| Zero balance |
±1.0 %F.S.
|
| Recommended excitation |
5-12 V DC
|
| Maximum excitation |
18 V DC
|
| Compensated temp range |
- 10 ~ 40 ºC
|
| Operation temp range |
- 35 ~ 70ºC
|
| Safe overload |
150% F.S.
|
| Ultimate overload |
200 % F.S.
|
| Protection class |
IP68
|
| Wiring |
Red: + Excitation Black: - Excitation
Green: + Signal White: - Signal
|